Vis enkel innførsel

dc.contributor.authorNandanwar, Sonali
dc.contributor.authorPatidar, Narayan P
dc.contributor.authorBrinda, Deva M
dc.contributor.authorKolhe, Mohan Lal
dc.date.accessioned2024-04-12T08:10:54Z
dc.date.available2024-04-12T08:10:54Z
dc.date.created2023-07-06T11:46:51Z
dc.date.issued2023
dc.identifier.citationNandanwar, S., Patidar, N. P., Brinda, D. M. & Kolhe, M. L. (2023). Real-time computing of power flows and node voltages in electrical energy network using decision trees. Cleaner Engineering and Technology, 15, Article 100654.en_US
dc.identifier.issn2666-7908
dc.identifier.urihttps://hdl.handle.net/11250/3126217
dc.description.abstractIn sustainable operation of electrical energy network, it is necessary to compute in real-time power flows and voltages at nodes for prioritizing power injection from clean energy resources. Intermittent renewable energy sources are likely to create voltage and power balancing issues and to maintain the voltage security of electrical network, real-time information of network power flows and bus voltages are required accurately and instantaneously. This paper presents an approach based on decision trees (DT) for real-time estimation of power flows within the electrical energy network and node voltages. A single tree structure is built for estimation of discrete (or categorical) as well as continuous values of line flows and node voltages of each line and node separately. A simple binary decision tree (BDT) and regression tree (RT) are used for estimation of discrete values and continuous values respectively. The training and testing patterns are generated by performing power flow analysis on an electrical energy network. Once the DT is trained, it estimates the line power flows and bus voltages with desired accuracy. The accuracy of the DT model is tested on a typical IEEE 30-bus system, using test patterns. Result shows that mean absolute error in case of line flow estimation for line number 1 and 10 are found to be 0.0028 p. u. and 0.0017 p. u. Also mean absolute error in case of bus voltage estimation for bus number 3 and 10 are found to be 0.0019 p. u. and 0.0016 p. u. Above results are suggestive of instantaneous estimationwith desired accuracy of line flow and bus voltages, which is the need of the hour for sustainable electrical energy network with integration of cleaner energy resources.Since, DT gives instantaneous result therefore suitable for real-time applications in sustainable electrical energy management system.en_US
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.relation.urihttps://www.sciencedirect.com/science/article/pii/S2666790823000599
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleReal-time computing of power flows and node voltages in electrical energy network using decision treesen_US
dc.title.alternativeReal-time computing of power flows and node voltages in electrical energy network using decision treesen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.rights.holder© 2023 The Author(s)en_US
dc.subject.nsiVDP::Teknologi: 500en_US
dc.source.volume15en_US
dc.source.journalCleaner Engineering and Technologyen_US
dc.identifier.doihttps://doi.org/10.1016/j.clet.2023.100654
dc.identifier.cristin2161209
dc.source.articlenumber100654en_US
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal