Vis enkel innførsel

dc.contributor.authorGangireddy, Narendra Kumar Reddy
dc.contributor.authorManikandan, M. Sabarimalai
dc.contributor.authorN. V. L., Narasimha Murty
dc.contributor.authorCenkeramaddi, Linga Reddy
dc.date.accessioned2023-06-27T10:41:31Z
dc.date.available2023-06-27T10:41:31Z
dc.date.created2023-06-17T14:16:53Z
dc.date.issued2023
dc.identifier.citationGangireddy, N. K. R., Manikandan, M. S., N. V. L. N. M. & Cenkeramaddi, L. R. (2023). Unified Quality-Aware Compression and Pulse-Respiration Rates Estimation Framework for Reducing Energy Consumption and False Alarms of Wearable PPG Monitoring Devices. IEEE Access, 11, 41708-41740.en_US
dc.identifier.issn2169-3536
dc.identifier.urihttps://hdl.handle.net/11250/3073435
dc.description.abstractDue to the high demands of tiny, compact, lightweight, and low-cost photoplethysmogram (PPG) monitoring devices, these devices are resource-constrained including limited battery power. Consequently, it highly demands frequent charge or battery replacement in the case of continuous PPG sensing and transmission. Further, PPG signals are often severely corrupted under ambulatory and exercise recording conditions, leading to frequent false alarms. In this paper, we propose a unified quality-aware compression and pulse-respiration rates estimation framework for reducing energy consumption and false alarms of wearable and edge PPG monitoring devices by exploring predictive coding techniques for jointly performing signal quality assessment (SQA), data compression and pulse rate (PR) and respiration rate (RR) estimation without the use of different domains of signal processing techniques that can be achieved by using the features extracted from the smoothed prediction error signal. By using the five standard PPG databases, the performance of the proposed unified framework is evaluated in terms of compression ratio (CR), mean absolute error (MAE), false alarm reduction rate (FARR), processing time (PT) and energy saving (ES). The compression, PR, RR estimation, and SQA results are compared with the existing methods and results of uncompressed PPG signals with sampling rates of 125 Hz and 25 Hz. The proposed unified qualityaware framework achieves an average CR of 4%, SQA (Se of 92.00%, FARR of 84.87%), PR (MAE: 0.46 ±1.20) and RR (MAE: 1.75 (0.65-4.45), PT (sec) of 15.34 ±0.01) and ES of 70.28% which outperforms the results of uncompressed PPG signal with a sampling rate of 125 Hz. Arduino Due computing platformbased implementation demonstrates the real-time feasibility of the proposed unified quality-aware PRRR estimation and data compression and transmission framework on the limited computational resources. Thus, it has great potential in improving energy-efficiency and trustworthiness of wearable and edge PPG monitoring devices.en_US
dc.language.isoengen_US
dc.publisherIEEEen_US
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/deed.no*
dc.titleUnified Quality-Aware Compression and Pulse-Respiration Rates Estimation Framework for Reducing Energy Consumption and False Alarms of Wearable PPG Monitoring Devicesen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.rights.holder© 2023 The Author(s)en_US
dc.subject.nsiVDP::Teknologi: 500en_US
dc.source.pagenumber41708-41740en_US
dc.source.volume11en_US
dc.source.journalIEEE Accessen_US
dc.identifier.doihttps://doi.org/10.1109/ACCESS.2023.3269584
dc.identifier.cristin2155465
dc.relation.projectNorges forskningsråd: 287918en_US
dc.relation.projectCouncil of Scientific and Industrial Research (CSIR) Fellow: 09/1059/ (0010)2015-EMR-1en_US