Vis enkel innførsel

dc.contributor.authorEbrahimi, Saeed Hasan
dc.contributor.authorChoux, Martin Marie Hubert
dc.contributor.authorHuynh, Khang
dc.date.accessioned2022-08-25T10:45:44Z
dc.date.available2022-08-25T10:45:44Z
dc.date.created2022-05-15T12:53:50Z
dc.date.issued2022
dc.identifier.citationHasan Ebrahimi, S., Choux, M. & Huynh, V.K. (2022). Real-Time Detection of Incipient Inter-Turn Short Circuit and Sensor Faults in Permanent Magnet Synchronous Motor Drives Based on Generalized Likelihood Ratio Test and Structural Analysis. Sensors. 22(9), 22.en_US
dc.identifier.issn1424-8220
dc.identifier.urihttps://hdl.handle.net/11250/3013513
dc.description.abstractThis paper presents a robust model-based technique to detect multiple faults in permanent magnet synchronous motors (PMSMs), namely inter-turn short circuit (ITSC) and encoder faults. The proposed model is based on a structural analysis, which uses the dynamic mathematical model of a PMSM in an abc frame to evaluate the system’s structural model in matrix form. The just-determined and over-determined parts of the system are separated by a Dulmage–Mendelsohn decomposition tool. Subsequently, the analytical redundant relations obtained using the over-determined part of the system are used to form smaller redundant testable sub-models based on the number of defined fault terms. Furthermore, four structured residuals are designed based on the acquired redundant sub-models to detect measurement faults in the encoder and ITSC faults, which are applied in different levels of each phase winding. The effectiveness of the proposed detection method is validated by an in-house test setup of an inverter-fed PMSM, where ITSC and encoder faults are applied to the system in different time intervals using controllable relays. Finally, a statistical detector, namely a generalized likelihood ratio test algorithm, is implemented in the decision-making diagnostic system resulting in the ability to detect ITSC faults as small as one single short-circuited turn out of 102, i.e., when less than 1% of the PMSM phase winding is short-circuited.en_US
dc.language.isoengen_US
dc.publisherMDPIen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleReal-Time Detection of Incipient Inter-Turn Short Circuit and Sensor Faults in Permanent Magnet Synchronous Motor Drives Based on Generalized Likelihood Ratio Test and Structural Analysisen_US
dc.title.alternativeReal-Time Detection of Incipient Inter-Turn Short Circuit and Sensor Faults in Permanent Magnet Synchronous Motor Drives Based on Generalized Likelihood Ratio Test and Structural Analysisen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.rights.holder© 2022 The Author(s)en_US
dc.subject.nsiVDP::Teknologi: 500en_US
dc.subject.nsiVDP::Teknologi: 500::Maskinfag: 570en_US
dc.source.pagenumber22en_US
dc.source.volume22en_US
dc.source.journalSensorsen_US
dc.source.issue9en_US
dc.identifier.doihttps://doi.org/10.3390/s22093407
dc.identifier.cristin2024668
dc.source.articlenumber3407en_US